HIOKI Digital Multimeter DT4252

HIOKI Digital Multimeter DT4252
Product Code: DT4252
Availability: Call For Availability

HIOKI Digital Multimeter DT4252

Speedy Performance of Professional Testing - Standard Models Provide Safety and Fast Response
 
  • ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
  • Low-pass filter (100Hz/500Hz) cuts high harmonics
  • Includes multiple measurement functions such as capacitance, and frequency
  • USB communications function supports PC measurements (optional)
  • Broad -10 (14°F) to 50°C (122°F) operating temperature range

Basic specifications

DC Voltage 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt.
AC Voltage  6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz
Basic accuracy: ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt.
DC Current 6.000 A / 10.00 A, 2 ranges, Basic accuracy: ±0.9 % rdg. ±5 dgt.
AC Current 40 to 500 Hz 6.000 A / 10.00 A, 2 ranges, Basic accuracy: ±1.4 % rdg. ±3 dgt.
(True RMS, crest factor 3, 40 Hz to 1kHz)
AC Current (use with the Clamp on probe) 45 to 1k Hz N/A
Temperature (use with DT4910) N/A
Voltage Detection N/A
C (capacitance) 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
Frequency AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges, 99.99 kHz (only for AC V) Basic accuracy: ±0.1 % rdg. ±1 dgt.
Continuity Check Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more Response time: 0.5 ms or more
Diode test Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
Other functions Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option)
Display Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Power supply LR03 alkaline batteries ×4, Continuous use: 130 hours (back light OFF)
Dimensions and mass 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (with batteries and holster)
Accessories TEST LEAD L9207-10 ×1, Holster ×1, Instruction Manual ×1, LR03 Alkaline Battery ×4

 